Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25.674
Filtrar
1.
BMJ Open ; 14(4): e082024, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637127

RESUMO

BACKGROUND: Postoperative pancreatic fistula (POPF) remains the most common and serious complication after distal pancreatectomy. Many attempts at lowering fistula rates have led to unrewarding insignificant results as still up to 30% of the patients suffer from clinically relevant POPF. Therefore, the development of new innovative methods and procedures is still a cornerstone of current surgical research.The cavitron ultrasonic surgical aspirator (CUSA) device is a well-known ultrasound-based parenchyma transection method, often used in liver and neurosurgery which has not yet been thoroughly investigated in pancreatic surgery, but the first results seem very promising. METHODS: The CUSA-1 trial is a randomised controlled pilot trial with two parallel study groups. This single-centre trial is assessor and patient blinded. A total of 60 patients with an indication for open distal pancreatectomy will be intraoperatively randomised after informed consent. The patients will be randomly assigned to either the control group with conventional pancreas transection (scalpel or stapler) or the experimental group, with transection using the CUSA device. The primary safety endpoint of this trial will be postoperative complications ≥grade 3 according to the Clavien-Dindo classification. The primary endpoint to investigate the effect will be the rate of POPF within 30 days postoperatively according to the ISGPS definition. Further perioperative outcomes, including postpancreatectomy haemorrhage, length of hospital stay and mortality will be analysed as secondary endpoints. DISCUSSION: Based on the available literature, CUSA may have a beneficial effect on POPF occurrence after distal pancreatectomy. The rationale of the CUSA-1 pilot trial is to investigate the safety and feasibility of the CUSA device in elective open distal pancreatectomy compared with conventional dissection methods and gather the first data on the effect on POPF occurrence. This data will lay the groundwork for a future confirmatory multicentre randomised controlled trial. ETHICS AND DISSEMINATION: The CUSA-1 trial protocol was approved by the ethics committee of the University of Heidelberg (No. S-098/2022). Results will be published in an international peer-reviewed journal and summaries will be provided in lay language to study participants and their relatives. TRIAL REGISTRATION NUMBER: DRKS00027474.


Assuntos
Pancreatectomia , Ultrassom , Humanos , Pancreatectomia/efeitos adversos , Pancreatectomia/métodos , Projetos Piloto , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Fístula Pancreática/etiologia , Fístula Pancreática/prevenção & controle , Fístula Pancreática/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
2.
Water Sci Technol ; 89(7): 1630-1646, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38619894

RESUMO

Due to the colloidal stability, the high compressibility and the high hydration of extracellular polymeric substances (EPS), it is difficult to efficiently dehydrate sludge. In order to enhance sludge dewatering, the process of ultrasonic (US) cracking, chitosan (CTS) re-flocculation and sludge-based biochar (SBB) skeleton adsorption of water-holding substances to regulate sludge dewaterability was proposed. Based on the response surface method, the prediction model of the specific resistance to filtration (SRF) and sludge cake moisture content (MC) was established. The US cracking time and the dosage of CTS and SBB were optimized. The results showed that the optimal parameters of the three were 5.08 s, 10.1 mg/g dry solids (DS) and 0.477 g/g DS, respectively. Meantime, the SRF and MC were 5.4125 × 1011 m/kg and 76.8123%, which significantly improved the sludge dewaterability. According to the variance analysis, it is found that the fitting degree of SRF and MC model is good, which also confirms that there is significant interaction and synergy between US, CTS and SBB, and the contribution of CTS and SBB is greater. Moreover, the process significantly improves the sludge's calorific value and makes its combustion more durable.


Assuntos
Quitosana , Esgotos , Ultrassom , Carvão Vegetal , Filtração , Água , Eliminação de Resíduos Líquidos/métodos
3.
Med Eng Phys ; 126: 104129, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621834

RESUMO

3D printed Poly Lactic Acid (PLA) bone plates exhibit limited three-point bending strength, restricting their viability in biomedical applications. The application of polydopamine (PDM) enhances the three-point bending strength by undergoing covalent interactions with PLA molecular structure. However, the heavy nature of PDM particles leads to settling at the container base at higher coating solution concentrations. This study investigates the impact of ultrasonic-assisted coating parameters on the three-point bending strength. Utilizing Response Surface Methodology (RSM) for statistical modeling, the study examines the influence of ultrasonic vibration power (UP), coating solution concentration (CC), and submersion time (TIME). RSM optimization recommended 100 % UP, 6 mg/ml CC, and 150 min TIME, resulting in maximum three-point bending strength of 83.295 MPa. Microscopic images from the comparative analysis revealed non-uniform coating deposition with mean thickness of 6.153 µm under normal coating. In contrast, ultrasonic-assisted coating promoted uniform deposition with mean thickness of 18.05 µm. The results demonstrate that ultrasonic-assisted coating induces PDM particle collision, preventing settling at the container base, and enhances three-point bending strength by 7.27 % to 23.24 % compared to the normal coating condition. This study emphasizes on the potential of ultrasonic-assisted coating to overcome the limitations of direct immersion coating technique.


Assuntos
Placas Ósseas , Ultrassom , Poliésteres/química , Ondas Ultrassônicas , Impressão Tridimensional
4.
BMC Oral Health ; 24(1): 417, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580933

RESUMO

BACKGROUND: Many instruments used in dentistry are rotary, such as handpieces, water syringes, and ultrasonic scalers that produce aerosols. The spray created by these instruments can carry, in addition to water, droplets of saliva, blood, and microorganisms, which can pose a risk of infections for healthcare professionals and patients. Due to the COVID-19 pandemic, this gained attention. OBJECTIVE: The aim was to carry out a systematic review of the evidence of the scope of the aerosol produced by ultrasonic scaler in environmental contamination and the influence of the use of intraoral suction reduction devices. DESIGN: Scientific literature was searched until June 19, 2021 in 6 databases: Pubmed, EMBASE, Web of science, Scopus, Virtual Health Library and Cochrane Library, without restrictions on language or publication date. Studies that evaluated the range of the aerosol produced by ultrasonic scaler during scaling/prophylaxis and the control of environmental contamination generated by it with the use of low (LVE) and high (HVE) volume evacuation systems were included. RESULTS: Of the 1893 potentially relevant articles, 5 of which were randomized controlled trials (RCTs). The meta-analysis of 3 RCTs showed that, even at different distances from the patient's oral cavity, there was a significant increase in airborne bacteria in the dental environment with the use of ultrasonic scaler. In contrast, when meta-analysis compared the use of HVE with LVE, there was no significant difference (P = 0.40/CI -0.71[-2.37, 0.95]) for aerosol produced in the environment. CONCLUSIONS: There is an increase in the concentration of bioaerosol in the dental environment during the use of ultrasonic scaler in scaling/prophylaxis, reaching up to 2 m away from the patient's mouth and the use of LVE, HVE or a combination of different devices, can be effective in reducing air contamination in the dental environment, with no important difference between different types of suction devices.


Assuntos
Terapia por Ultrassom , Humanos , Ultrassom , Aerossóis e Gotículas Respiratórios , Aerossóis/efeitos adversos , Água , Raspagem Dentária
5.
Am J Dent ; 37(1): 24-28, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38458979

RESUMO

PURPOSE: To assess and compare the effects of sonic and ultrasonic instrumentation on shear bond strength (SBS) and investigate the influence of adhesive system application modes (etch&rinse/self-etch) on SBS. METHODS: In this experimental study, 45 extracted sound human molars were selected. Mesial and distal surfaces of the teeth were abraded until 90 smooth enamel surfaces were obtained. Specimens were divided into two groups, with half (N= 45) conditioned in etch&rinse mode and the remaining (N= 45) in self-etch mode using Tetric N Bond Universal. Composite resin discs were produced on these surfaces by filling Teflon molds. All specimens were aged via thermocycling. Each group was further divided into three more groups (n= 15) according to the type of periodontal instrumentation (ultrasonic, sonic or none). SBS values were recorded and analyzed using two-way ANOVA. Fracture sites were examined under a stereomicroscope. RESULTS: The type of periodontal instrumentation had no significant effect on SBS values, whether sonic, ultrasonic or their absence (P= 0.945). The type of adhesive system mode had a significant influence on the shear bond strength values. Etch&rinse groups had significantly higher shear bond strength values than self-etch groups (P< 0.001). CLINICAL SIGNIFICANCE: This study reassures practitioners that sonic and ultrasonic instruments are safe for enamel bonding and highlights the importance of selecting adhesive techniques for optimal restorative outcomes.


Assuntos
Colagem Dentária , Cimentos Dentários , Humanos , Idoso , Cimentos Dentários/química , Adesivos Dentinários/química , Cimentos de Resina , Colagem Dentária/métodos , Ultrassom , Resinas Compostas/química , Esmalte Dentário , Teste de Materiais , Resistência ao Cisalhamento
6.
Science ; 383(6687): 1096-1103, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38452063

RESUMO

Monitoring homeostasis is an essential aspect of obtaining pathophysiological insights for treating patients. Accurate, timely assessments of homeostatic dysregulation in deep tissues typically require expensive imaging techniques or invasive biopsies. We introduce a bioresorbable shape-adaptive materials structure that enables real-time monitoring of deep-tissue homeostasis using conventional ultrasound instruments. Collections of small bioresorbable metal disks distributed within thin, pH-responsive hydrogels, deployed by surgical implantation or syringe injection, allow ultrasound-based measurements of spatiotemporal changes in pH for early assessments of anastomotic leaks after gastrointestinal surgeries, and their bioresorption after a recovery period eliminates the need for surgical extraction. Demonstrations in small and large animal models illustrate capabilities in monitoring leakage from the small intestine, the stomach, and the pancreas.


Assuntos
Implantes Absorvíveis , Fístula Anastomótica , Trato Gastrointestinal , Ultrassom , Animais , Humanos , Homeostase , Estômago , Trato Gastrointestinal/cirurgia , Fístula Anastomótica/diagnóstico por imagem , Modelos Animais
7.
Science ; 383(6687): 1058-1059, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38452097

RESUMO

An implant could allow at-home monitoring of deep-tissue changes after surgery.


Assuntos
Implantes Absorvíveis , Ultrassom , Ultrassonografia , Homeostase
8.
Water Environ Res ; 96(3): e11011, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38477462

RESUMO

The current study focuses on the degradation of Procion brilliant yellow H-E6G, an azo dye, using ultrasonic and hydrodynamic cavitation (HC), evaluating the impact of various parameters on the extent of degradation. The use of only ultrasound showed less oxidation capacity as indicated by only 19.1% degradation at an optimized power of 140 W, pH of 2.5, temperature of 40°C, and initial dye concentration of 15 ppm. The effectiveness of hybrid approaches involving US + H2 O2 , US + Fenton, and US + H2 O2 + potassium persulfate (KPS) was subsequently evaluated under optimized conditions. A notable enhancement in decolorization extent was observed for combined operations, including US + H2 O2 , US + Fenton, and US + H2 O2 + KPS (dual oxidant scheme) with the actual decolorization extents as 80.6%, 85%, and 92.2% respectively. An optimized scheme of US + H2 O2 + KPS was also utilized to decolorize the dye at a pilot scale using a US flow cell and also an HC reactor that yielded 91.8% and 88% reductions in initial concentration. The dye decolorization was elucidated to follow first-order kinetics for all the individual and combination approaches. The obtained values of the rate constants were also utilized for the evaluation of the synergistic index. A toxicity analysis was also performed on the dye, both before and following treatment, utilizing two bacterial strains. A comparative analysis of various treatment approaches has been presented focusing on factors such as cavitational yield, operational expenses, and energy requirements. The study elucidated that the combination of US + H2 O2 + KPS effectively removes Procion brilliant yellow H-E6G giving 92.2% as the maximum degradation at an operating cost of 0.1862 $/L. PRACTITIONER POINTS: First depiction of cavitative degradation of Procion brilliant yellow H-E6G Optimizing the equipment operating parameters and chemical oxidants Demonstration of optimized treatment scheme at pilot scale Evaluation of various approaches based on synergy and costs of treatment US + H2 O2  + KPS is the best approach for dye degradation.


Assuntos
Compostos Azo , Benzenossulfonatos , Peróxido de Hidrogênio , Oxidantes , Hidrodinâmica , Ultrassom
9.
Environ Sci Pollut Res Int ; 31(18): 26580-26591, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451460

RESUMO

Dye wastewater is a type of high-concentration, high chromaticity, and high salinity organic wastewater, which is generally treated with activated carbon adsorbent. The effective regeneration of granular activated carbon (GAC) is the key to reducing the operating cost of GAC in the wastewater treatment process. The regeneration characteristics of saturated GAC adsorbed on 288 orange dye wastewater were studied by using the ultrasonic coupled thermal regeneration method. The results showed that the regeneration efficiency of GAC adsorbed on 288 orange dye wastewater increased with the increase of ultrasound power. The optimal ultrasound frequency and regeneration temperature were determined to be 45 kHz and 60 ℃, and the relationship between regeneration times and carbon loss rate was explored. The combination of ultrasound and high-temperature heating methods has successfully improved the regeneration efficiency of GAC and significantly reduced the high-temperature thermal regeneration time of GAC, thereby reducing the mass loss rate of GAC. The performance changes of fresh activated carbon (FAC), saturated activated carbon (SAC), ultrasonic regeneration of activated carbon (UAC), and thermal regeneration of activated carbon (TAC) during the combined regeneration process were explored by characterizing the regenerated GAC. Infrared characterization showed that the C-O group of GAC was significantly weakened after coupling treatment, indicating that ultrasonic treatment can significantly enhance the desorption effect of thermal regeneration. The microjet, shock wave, and cavitation effects generated by ultrasonic treatment restore the specific surface area of GAC, mainly increasing the micropore volume and pore size of GAC, and enhancing the treatment effect of thermal regeneration.


Assuntos
Carvão Vegetal , Águas Residuárias , Carvão Vegetal/química , Adsorção , Águas Residuárias/química , Temperatura , Carbono/química , Purificação da Água/métodos , Ultrassom , Eliminação de Resíduos Líquidos/métodos , Poluentes Químicos da Água/química
10.
J Feline Med Surg ; 26(3): 1098612X241231471, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38546192

RESUMO

OBJECTIVES: Systemic arterial hypertension is a common occurrence and can have serious adverse consequences in cats. Therefore, measuring blood pressure is very important. There are many indirect blood pressure measurement devices available. This study compared Doppler, oscillometric (petMAP Graphic II, SunTech Vet20, the Cardell Insight-X0000) and high-definition oscillometry devices for the non-invasive measurement of blood pressure in conscious cats. METHODS: In this prospective study, blood pressure was measured in 32 cats using the different devices according to the recommendations of the American College of Veterinary Internal Medicine Consensus Statement. Blood pressures (systolic blood pressure [SBP], diastolic blood pressure [DBP], mean arterial pressure [MAP]), time to complete measurements, number of attempts needed, coefficient of variation (CV) between the blood pressure measurements of the different devices, ease of completing measurements and apparent stress level of the cat were assessed. RESULTS: There was a significant difference between devices in the time taken to obtain blood pressure readings and the number of attempts necessary to obtain six reliable measurements. The CV of the Doppler device was significantly smaller than that of the rest of the devices, but there were no other differences between the devices. The mean SBP, DBP and MAP measured by the petMAP device were significantly higher than the measurements from the other devices. The perceived ease of measurement was not significantly different between the various machines. The perceived level of stress of measurement with the Doppler device was significantly higher compared with the other devices but did not lead to an increased SBP. CONCLUSIONS AND RELEVANCE: Using a Doppler device to measure blood pressure in conscious cats is fast, relatively easy and gives reliable results. A disadvantage is that the Doppler device can only measure SBP, while oscillometric devices also provide DBP and MAP. However, in veterinary medicine, systolic hypertension is considered the most relevant.


Assuntos
Determinação da Pressão Arterial , Ultrassom , Gatos , Animais , Pressão Sanguínea/fisiologia , Oscilometria/veterinária , Oscilometria/métodos , Estudos Prospectivos , Determinação da Pressão Arterial/veterinária
11.
ACS Chem Neurosci ; 15(8): 1643-1651, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38546732

RESUMO

The rapid amplification and sensitive detection of α-synuclein (αSyn) seeds is an efficient approach for the early diagnosis of Parkinson's disease. Ultrasonication stands out as a promising method for the rapid amplification of αSyn seeds because of its robust fibril fragmentation capability. However, ultrasonication also induces the primary nucleation of αSyn monomers, deteriorating the seed detection sensitivity by generating seed-independent fibrils. In this study, we show that an addition of surfactants to the αSyn monomer solution during αSyn seed detection under ultrasonication remarkably improves the detection sensitivity of the αSyn seeds by a factor of 100-1000. Chemical kinetic analysis reveals that these surfactants reduce the rate of primary nucleation while promoting the fragmentation of the αSyn fibrils under ultrasonication. These effects are attributed to the modification of the ultrasonic cavitation surface by the surfactants. Our study enhances the utility of ultrasonication in clinical assays targeting αSyn seeds as the Parkinson's disease biomarker.


Assuntos
Doença de Parkinson , alfa-Sinucleína , Humanos , Ultrassom , Cinética , Tensoativos , Amiloide , Proteínas Amiloidogênicas
12.
Talanta ; 273: 125879, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38490022

RESUMO

In order to improve the living standards of diabetes patients and reduce the negative health effects of this disease, the medical community has been actively searching for more effective treatments. In recent years, an artificial pancreas has emerged as an important approach to managing diabetes. Despite these recent advances, meeting the requirements for miniaturized size, accurate sensing and large-volume pumping capability remains a great challenge. Here, we present a novel miniaturized artificial pancreas based on a long microtube sensor integrated with an ultrasonic pump. Our device meets the requirements of achieving both accurate sensing and high pumping capacity. The artificial pancreas is constructed based on a long microtube that is low cost, painless and simple to operate, where the exterior of the microtube is fabricated as a glucose sensor for detecting diabetes and the interior of the microtube is used as a channel for delivering insulin through an ultrasonic pump. This work successfully achieved closed-loop control of blood glucose and treatment of diabetes in rats. It is expected that this work can open up new methodologies for the development of microsystems, and advance the management approach for diabetes patients.


Assuntos
Diabetes Mellitus Tipo 1 , Pâncreas Artificial , Dispositivos Eletrônicos Vestíveis , Humanos , Animais , Ratos , Hipoglicemiantes/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Ultrassom , Insulina , Glicemia
13.
Ultrasonics ; 139: 107274, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38428161

RESUMO

Numerous quantitative ultrasound imaging techniques have demonstrated superior monitoring performance for thermal ablation when compared to conventional ultrasonic B-mode imaging. However, the absence of comparative studies involving various quantitative ultrasound imaging techniques hinders further clinical exploration. In this study, we simultaneously reconstructed ultrasonic Nakagami imaging, ultrasonic horizontally normalized Shannon entropy (hNSE) imaging, and ultrasonic differential attenuation coefficient intercept (DACI) imaging from ultrasound backscattered envelope data collected during high-intensity focused ultrasound ablation treatment. We comprehensively investigated their performance differences through qualitative and quantitative analyses, including the calculation of contrast-to-noise ratios (CNR) for ultrasonic images, receiver operating characteristic (ROC) analysis with corresponding indicators, the analysis of lesion area fitting relationships, and computational time consumption comparison. The mean CNR of hNSE imaging was 10.98 ± 4.48 dB, significantly surpassing the 3.82 ± 1.40 dB (p < 0.001, statistically significant) of Nakagami imaging and the 2.45 ± 0.74 dB (p < 0.001, statistically significant) of DACI imaging. This substantial difference underscores that hNSE imaging offers the highest contrast resolution for lesion recognition. Furthermore, we evaluated the ability of multiple ultrasonic parametric imaging to detect thermal ablation lesions using ROC curves. The area under the curve (AUC) for hNSE was 0.874, exceeding the values of 0.848 for Nakagami imaging and 0.832 for DACI imaging. Additionally, hNSE imaging exhibited the strongest linear correlation coefficient (R = 0.92) in the comparison of lesion area fitting, outperforming Nakagami imaging (R = 0.87) and DACI imaging (R = 0.85). hNSE imaging also performs best in real-time monitoring with each frame taking 6.38 s among multiple ultrasonic parametric imaging. Our findings unequivocally demonstrate that hNSE imaging excels in monitoring HIFU ablation treatment and holds the greatest potential for further clinical exploration.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Ultrassom , Fígado/diagnóstico por imagem , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Ultrassonografia/métodos
14.
Ultrasonics ; 139: 107299, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38508083

RESUMO

Dermal collagen is the most abundant component of human skin and has a network structure that regulates the mechanical properties of the skin. Therefore, non-invasive characterization of the collagen network would be beneficial for the evaluation of skin conditions. The microscopic substructures of the network, which are individual bundles and fibers, have been optically investigated. However, the macroscopic structure of the collagen network has not been assessed. To evaluate the dermal collagen network, we developed two new indicators, volume filling factor (VFF) and collagen fiber texture (CFT), to analyze three-dimensional echo intensity maps of high-frequency ultrasonic microscopy. By identifying the difference in the elastic modulus components of the dermal layer of facial skin, the density and texture of the collagen network were characterized using VFF and CFT, respectively. These new indicators revealed that the density decreased and the texture became fine with facial age. This study demonstrates that ultrasonic microscopy is useful for investigating skin conditions, paving the way for diagnostic applications in dermatology and aesthetic medicine.


Assuntos
Microscopia , Ultrassom , Humanos , Bochecha/diagnóstico por imagem , Pele/diagnóstico por imagem , Colágeno
15.
J Environ Manage ; 356: 120589, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38531126

RESUMO

The leaching of dissolved organic matter (DOM) from the sludge into the liquid phase is induced by ultrasound. However, there is limited investigation into the structure and molecular composition of sludge DOM in this process. The molecular structure and composition of sludge DOM in ultrasonic treatment were comprehensively elucidated in this study. The sludge dissolved organic carbon (DOC) and three-dimensional fluorescence spectroscopy (3D-EEM) image had most significant change at 15-min ultrasonic time and 1.2 W/mL ultrasonic density, respectively. Gas Chromatography-Mass Spectrometry (GC-MS) analysis indicated that ultrasonic treatment of sludge reduced the macromolecules to small molecules in DOM. Then, electrospray ionization Fourier-transform ion cyclotron resonance mass spectrometry (ESI FT-ICR-MS) analysis revealed that lignin, tannins, and carbohydrates were the main components of sludge DOMs after ultrasound treatment. analysis revealed that lignin, tannins, and carbohydrates were the main components of sludge DOMs after ultrasound treatment. Furthermore, through the Van Krevelen analysis, the major components were CHO (48.50%) and CHOS (23.20%) in the DOM of ultrasonicated sludge. This research provides the basis for the practical application of ultrasonic treatment of sludge and provides basic information for DOM components.


Assuntos
Matéria Orgânica Dissolvida , Esgotos , Lignina , Taninos , Ultrassom , Carboidratos
16.
JASA Express Lett ; 4(3)2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38467469

RESUMO

Echolocating big brown bats (Eptesicus fuscus) broadcast downward frequency-modulated sweeps covering the ultrasonic range from 100-23 kHz in two harmonics. They perceive target range from the time delay between each broadcast and its returning echo. Previous experiments indicated that the bat's discrimination acuity for broadcast-echo delay declines when the lowest frequencies (23-35 kHz) in the first harmonic of an echo are removed. This experiment examined whether echo detection is similarly impaired. Results show that detection thresholds for echoes missing these lowest frequencies are raised. Increased thresholds for echoes differing in spectra facilitates the bat's ability to discriminate against clutter.


Assuntos
Quirópteros , Ecolocação , Animais , Ultrassom , Terapia Comportamental , Distúrbios da Fala
17.
eNeuro ; 11(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38490744

RESUMO

Vocalization, a means of social communication, is prevalent among many species, including humans. Both rats and mice use ultrasonic vocalizations (USVs) in various social contexts and affective states. The motor cortex is hypothesized to be involved in precisely controlling USVs through connections with critical regions of the brain for vocalization, such as the periaqueductal gray matter (PAG). However, it is unclear how neurons in the motor cortex are modulated during USVs. Moreover, the relationship between USV modulation of neurons and anatomical connections from the motor cortex to PAG is also not clearly understood. In this study, we first characterized the activity patterns of neurons in the primary and secondary motor cortices during emission of USVs in rats using large-scale electrophysiological recordings. We also examined the axonal projection of the motor cortex to PAG using retrograde labeling and identified two clusters of PAG-projecting neurons in the anterior and posterior parts of the motor cortex. The neural activity patterns around the emission of USVs differed between the anterior and posterior regions, which were divided based on the distribution of PAG-projecting neurons in the motor cortex. Furthermore, using optogenetic tagging, we recorded the USV modulation of PAG-projecting neurons in the posterior part of the motor cortex and found that they showed predominantly sustained excitatory responses during USVs. These results contribute to our understanding of the involvement of the motor cortex in the generation of USV at the neuronal and circuit levels.


Assuntos
Córtex Motor , Substância Cinzenta Periaquedutal , Humanos , Ratos , Camundongos , Animais , Ultrassom , Vocalização Animal/fisiologia , Neurônios/fisiologia
18.
Int J Biol Macromol ; 264(Pt 1): 130526, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38431008

RESUMO

Although a promising method for lignin depolymerization, photocatalysis faces the challenge of low efficiency. In this study, MoS2/ZnO heterojunction catalysts, endowed with piezocatalysis and photocatalytic capabilities, were crafted through Zn ion intercalation for the depolymerization of phenoxyphenylethanol (PP-ol) and alkali lignin. Then, the synergistic interplay between ultrasonic-induced piezoelectric fields and heterojunctions was analyzed. The amalgamation of the piezoelectric field and heterojunction in MoS2/ZnO catalysts resulted in a diminished photogenerated hole/electron recombination efficiency, thereby fostering the generation of ·OH during the reaction. This pivotal role of ·OH emerged as a crucial reactive substance, converting 95.8 % of PP-ol through ß-O-4 bond breaking within a 3-h treatment. By incorporating ultrasonic, the contact probability of PP-ol with the catalyst was significantly improved, resulting in efficient conversion even with a reduced amount of acetonitrile in the solvent system (20 %). Furthermore, ultrasonic-light methods show high efficiency for depolymerizing Alkali lignin (AL), with 33.2 % of lignin undergoing depolymerization in a 4-h treatment. This treatment simultaneously reduces the molecular weight of AL and cleaves numerous chemical bonds within it. Overall, this work presents a green approach to lignin depolymerization, providing insights into the synergistic action of ultrasonic and photocatalysis.


Assuntos
Lignina , Óxido de Zinco , Lignina/química , Ultrassom , Molibdênio , Catálise , Álcalis
19.
Chemosphere ; 354: 141676, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38462187

RESUMO

The existence of pollutants, such as toxic organic dye chemicals, in water and wastewater raises concerns as they are inadequately eliminated through conventional water and wastewater treatment methods, including physicochemical and biological processes. Ultrasonic treatment has emerged as an advanced treatment process that has been widely applied to the decomposition of recalcitrant organic contaminants. Ultrasonic treatment has several advantages, including easy operation, sustainability, non-secondary pollutant production, and saving energy. This review examines the elimination of dye chemicals and categorizes them into cationic and anionic dyes based on the existing literature. The objectives include (i) analyzing the primary factors (water quality and ultrasonic conditions) that influence the sonodegradation of dye chemicals and their byproducts during ultrasonication, (ii) assessing the impact of the different sonocatalysts and combined systems (with ozone and ultraviolet) on sonodegradation, and (iii) exploring the characteristics-based removal mechanisms of dyes. In addition, this review proposes areas for future research on ultrasonic treatment of dye chemicals in water and wastewater.


Assuntos
Poluentes Ambientais , Ozônio , Poluentes Químicos da Água , Purificação da Água , Águas Residuárias , Corantes/química , Ultrassom , Poluentes Químicos da Água/química , Purificação da Água/métodos
20.
Braz Dent J ; 35: e245611, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537014

RESUMO

This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Humanos , Preparo de Canal Radicular/métodos , Ultrassom , Irrigantes do Canal Radicular , Irrigação Terapêutica/métodos , Microtomografia por Raio-X , Dentina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...